EI30 - Encapsulated PCB Mount 50/60Hz Transformer - 0.6-4.8VA
Our comprehensive selection of products also includes a series of EI30 safety transformers for PCB mounting. High-quality encapsulated vacuum potted short-circuit proof transformers. Output power from 0.6VA.
|
|
|
|
|
|
|
|
View from PCB |
|
Solder pins 0.8 mm Ø |
- Grid 5 mm |
Type |
|
|
|
|
|
* |
Stack height mm |
Case height mm |
Weight g |
EI30-X10/7.../.. |
70°C/B |
6...24V - 0.70 VA |
2x6...12V - 2x0.30 VA |
x |
x |
ukf |
5.0 |
15.5 |
44 |
EI30-X6/7.../... |
70°C/B |
6...28V - 1.50 VA |
2x6...14V - 2x0.65 VA |
x |
x |
ukf |
10.5 |
23.0 |
75 |
EI30-X6/4.../... |
40°C/B |
6...26V - 1.70 VA |
2x6...13V - 2x0.75 VA |
x |
|
ukf |
10.5 |
23.0 |
75 |
EI30-Y7/7.../... |
70°C/B |
6...29V - 1.70 VA |
2x6...14V - 2x0.75 VA |
x |
x |
ukf |
12.5 |
24.7 |
85 |
EI30-Y7/4.../... |
40°C/B |
6...27V - 2.00 VA |
2x6...13V - 2x0.90 VA |
x |
|
ukf |
12.5 |
24.7 |
85 |
EI30-Y8/7.../... |
70°C/B |
6...28V - 2.00 VA |
2x6...14V - 2x0.90 VA |
x |
x |
ukf |
15.0 |
27.3 |
98 |
EI30-Y8/4.../... |
40°C/B |
6...27V - 2.40 VA |
2x6...13V - 2x1.10 VA |
x |
|
ukf |
15.0 |
27.3 |
98 |
EI30-Y8F/7.../... |
70°C/B |
6...32V - 2.40 VA |
2x6...16V - 2x1.10 VA |
x |
x |
ukf |
15.0 |
27.3 |
98 |
EI30-Y9/7.../... |
70°C/B |
6...28V - 2.30 VA |
2x6...14V - 2x1.00 VA |
x |
x |
ukf |
18.0 |
30.2 |
117 |
EI30-Y9F/7.../... |
70°C/B |
6...30V - 2.70 VA |
2x3...15V - 2x1.25 VA |
x |
x |
ukf |
18.0 |
30.2 |
117 |
EI30-Y9/4.../... |
40°C/B |
6...28V - 2.80 VA |
2x6...14V - 2x1.30 VA |
x |
|
ukf |
18.0 |
30.2 |
117 |
EI30-Y10/7.../... |
70°C/B |
6...30V - 2.80 VA |
2x6...15V - 2x1.40 VA |
x* |
|
ukf |
23.0 |
34.4 |
140 |
EI30-Y10/4.../... |
40°C/B |
6...28V - 3.60 VA |
2x6...14V - 2x1.80 VA |
|
|
ukf |
23.0 |
34.4 |
140 |
EI30-Y10F/7.../... |
70°C/B |
6...32V - 4.00 VA |
2x6...16V - 2x1.80 VA |
|
|
bkf |
23.0 |
34.4 |
140 |
EI30-Y10F/4.../... |
40°C/B |
6...30V - 4.80 VA |
2x6...15V - 2x2.20 VA |
|
|
bkf |
23.0 |
34.4 |
140 |
- Approved to EN 61558, UL 506 UL 1585 CI.2 and C1.3, C22.2
- Vacuum cast
- Two chamber coil
- Safety class II
- Protective system IP 00
- Absolutely short circuit proof (*ukf),
or conditionally short circuit proof (*bkf) through temperature fuse
Note: If using conditionally short circuit proof transformer type (*bkf), no strip conductors may be guided between the primary connecting pins on the component side, because in this area there is an unprotected live soldering terminal
Variants available upon request
Top of page
|
Nordtek Denmark - current sensor, ei30, ee20, pcb transformer, vergossen, plug in transformer, topswitch, simple switcher
Nordtek Com - transformer design, magnetics, impedance, transformer ac, toroids
strommessung, netztrafo, power supply,voltage transformer, telecom transformer, pulse
current sense transformer, drossel, current sense transformer, inductive, ferrite, kleintransformatoren
inductor, inductance, 3c85, 3f3, power transformer, toroid, 50/60hz, line transformer, emi
Transformers, Chokes, Toroids for Audio, Switchmode, Power Supply, Current Sense,
electronic starter, flicker starter, fluorescent lamps, safety starter, lamp starter, glow starters, tubestarter, rapid, ts8, sunbed, halogen transformer
|