MHJ -3kV Interface Transformer Modules
Features
- excellent output characteristics ensure compliance with CCITT.I.430 pulse waveform template when used with recommended IC pairing
- SMD modules are designed for pick and place compatibility
- excellent and consistent balance between windings
- modular design maximizes suppression effectivity and transmission properties
- compact module eliminates three components reducing assembly and storage cost
- full compatibility with all common IC´s
- operating temperature:-40°C to +85°C
- storage temperature: -40°C to +125°C
Standard Packaging: Tape and Reel |
|
|
|
|
Electrical Specifications @ 25°C |
|
Turns Ratio: Bold = IC side windings |
3kV Modules comply with Reinforced Insulation Level EN60950
Part Number |
LP
(mH Min.) |
Turns Ratio
±1% |
LL
(µH Max.) |
^IDC
(mA) |
CC
(pF Max.) |
RCUP
(Ohms) |
RCUS
(Ohms) |
VP
(Vrms) |
Schematic |
MHJ-200B1-XXX
MHJ-240B1-XXX
MHJ-230B1-XXX |
30
30
30 |
1:1:1:1
1:1:2:2
1:1:2.5:2.5 |
10
10
10 |
4
4
4 |
75
75
75 |
1.7
1.7
1.7 |
1.9
3.7
4.4 |
3,000
3,000
3,000 |
A
A
A |
Common Mode Quad Choke |
Basic PIN Suffix
(Example: MHJ-240B1-502) |
LN
(µH)
|
RCU
(Ohms)
|
0 |
No Choke
|
-470 |
47 |
0.4 |
-101 |
100 |
0.6 |
-501 |
500 |
0.4 |
-502 |
5,000 |
1.1 |
-123 |
12,000 |
1.8 |
|
|
Test Conditions:
So Transformer modules comply with Reinforced Insulation Level EN60950:1992/A4: 1997, para. 2.9.4.4 when tested in accordance with 6.4.1
- Polarity and Turns Ratio: w1 : w2 : w3 : w4:1:1 %
- Inductance: 30mH Minimum, line side windings (w3 w4) in series @ 10kHz, 100mV
- Leakage Inductance: 10µH Max. @ 100kHz, 100mV
- Quad Choke Inductance: 100kHz, 20mV
- Winding Capacitance: CW 150pF Max. (w3 w4)
- Coupling Capacitance: CC 75pF Max. (w3 w4 tow1 w2) @ 10kHz, 100mV
- High Voltage Test: 4kV, 1 minute U(w3 w4 to w1 w2)
High Voltage Pulse Test: UPULSE (w3 w4 to w1 w2); 10kVOP for 1.2µs/50µs wave form
UPULSE (w3 w4 to w1 w2); 10kVOP for 10µs/700µs wave form
|
Top of page
|
Nordtek Denmark - current sensor, ei30, ee20, pcb transformer, vergossen, plug in transformer, topswitch, simple switcher
Nordtek Com - transformer design, magnetics, impedance, transformer ac, toroids
strommessung, netztrafo, power supply,voltage transformer, telecom transformer, pulse
current sense transformer, drossel, current sense transformer, inductive, ferrite, kleintransformatoren
inductor, inductance, 3c85, 3f3, power transformer, toroid, 50/60hz, line transformer, emi
Transformers, Chokes, Toroids for Audio, Switchmode, Power Supply, Current Sense,
electronic starter, flicker starter, fluorescent lamps, safety starter, lamp starter, glow starters, tubestarter, rapid, ts8, sunbed, halogen transformer
|